A800 CI
Cell Incubator
_______________
Cell incubators are about simplicity and flexibility. But in lab automation settings, it is also about stability and accuracy. With superior active environmental and humidity control, the A800 CI is the ultimate solution for automated storage. And seamless integration makes this intelligent storage system the perfect addition to Stratedigm’s product suite. From the high-performance components to the compact size, the A800 CI represents the depth of technology at the height of design.
_______________
Features:
- Flexible configuration:
- Benchtop option
- Floor option
- Wide temperature range option
- Active humidity control
- Compact footprint
- Up to 44 plate capacity
- Optional upgrades:
- True orbital shaking
- Fast CO2 Gassing
- Preventative Automated Daily Decon
- Full System Decon
Literature
Videos
A800 CI-SR (Short Range)
Climate Options:
- Temperature: 35-50° C
- Humidity: 95% max
Optional Accessories:
- Fast CO2 Gassing Option: linear precision IR absorption detector control, display and remote readout, 0-10% volume Gassing conditioner
- Shaking: orbital, 2 mm Amplitude, 1000 rpm max
- Preventative Automated Daily Decon
- Full System Decon
Configuration:
- Available in floor (positioned on the floor) or benchtop (positioned on the table) configurations
System Compatibility:
- Software: Stratedigm CellCapTure software
- Flow Cytometer: any S1000 or SE520 series analyzer
- Requires use of Stratedigm A600 HTAS and A700 HTH for integration
Plate Compatibility:
- 24-well: flat-bottom and round-bottom
- 96-well: U-bottom, V-bottom, flat-bottom, and deep-well
- 384-well: flat-bottom
Other Specifications:
- Size: < 19″ W x 17″ D x 45″ H depending on upgrade options
- Weight: 88 kg
- Operating power: 450 W
A800 CI-WR (Wide Range)
Climate Features:
- Temperature: 4-50° C
- Humidity: 90-95% max
Optional Accessories:
- Fast CO2 Gassing Option: linear precision IR absorption detector control, display and remote readout, 0-10% volume Gassing conditioner
- Shaking: orbital, 2 mm Amplitude, 1000 rpm max
- Preventative Automated Daily Decon
- Full System Decon
Configuration:
- Available in floor (positioned on the floor) or benchtop (positioned on the table) configurations
System Compatibility:
- Software: Stratedigm CellCapTure software
- Flow Cytometer: any S1000 or SE520 series analyzer
- Requires use of Stratedigm A600 HTAS and A700 HTH for integration
Plate Compatibility:
- 24-well: flat-bottom and round-bottom
- 96-well: U-bottom, V-bottom, flat-bottom, and deep-well
- 384-well: flat-bottom
Other Specifications:
- Size: < 19″ W x 17″ D x 45″ H depending on upgrade options
- Weight: 125 kg
- Operating power: 500 W