SE520EON

Flow Cytometer

_______________

We know that people demand performance and reliability from their flow cytometers, even for standard applications. But uncompromised performance simply would not be achievable at a lower price point with conventional entry-level systems. So we designed our SE520EON benchtop flow cytometer with the same patented technologies as our S1000 series—without the same price tag. Our SE520EON may be a small flow cytometer, but it’s big on performance.

_______________



Features

  • Fixed configuration with 2 lasers (488 nm and 640 nm) and 6 colors
  • Based on the same performance and patented technology as the S1000EON
  • Complete compatibility with Stratedigm’s full automation suite
Left Angled View of Stratedigm SE520EXi 2 Laser, 6 Color Flow Cytometer
Left Angled View of Stratedigm SE520EXi 2 Laser, 6 Color Flow Cytometer
Left Angled View of Stratedigm SE520EXi 2 Laser, 6 Color Flow Cytometer
SE520EON Right
SE520EON Front
SE520EON Left
previous arrow
next arrow
SE520EON Right
SE520EON Front
SE520EON Left
previous arrow
next arrow

Configure Your Product

Download Tech Specs

Download Brochure


Literature

Videos

Technical Specifications

Laser:

  • System is designed to support 2 lasers with spatial separation
  • Laser options:
    • Solid-state 488 nm – 150 mW
    • Solid-state 640 nm – 100 mW

Detector Parameters & Data Acquisition:

  • Dynamic Range:
    • 5 decades for acquisition
    • 7 decades for analysis
  • Forward scatter (FSC) – enables separation of unfixed platelets from noise
    • FSC resolution: < 500 nm polystyrene beads
    • FSC scales: log & linear
    • FSC: parameters: width, peak-height; area
    • Optional FSC photomultiplier (PMT) detector
  • Side scatter (SSC)- resolves lympho-, mono- , and granulocytes
    • SSC resolution: < 200 nm polystyrene beads
    • SSC scales: log & linear
    • SCC parameters: width, peak-height, area
  • Fluorescence channels:
    • Standard number of colors: 6
    • Sensitivity: < 100 MESF
    • PMT scales: log & linear
    • PMT parameters: width, peak-height, area
    • Time: 13 µsec resolution

Analysis Rate & Carryover

  • Analysis rate: 20,000 events/ sec
  • Carryover: < 0.1% automatic backlash between samples

Sample Input:

  • Dead volume: < 8 μL
  • Minimum sample volume: < 20 μL
  • Maximum particle size: 40 μm
  • Patented low insertion force single tube loading

Fluidics Tray:

  • Integrated fluidics tray does not increase the footprint of the instrument
  • Automated startup, shutdown, and cleaning cycles
  • Automated decontamination procedure using onboard cleaning solution for all components in contact with sample
  • Tank Capacity: 4 L sheath, 4 L waste, 4 L auxiliary solution
  • Optional automated sheath tank fill and waste drainage

Operating Conditions:

  • Operating Conditions: 60-86 °F (15-30 °C)
  • Size (including fluidics tray): 21.5″ W x 21″ D x 24″ H (54.6 cm W x 53.3 cm D x 61 cm H)
  • Weight (including fluidics tray): < 70 lbs (35 kg)
  • Power: 110/115/230 VAC, 50-60 Hz

Patents:

U.S. Patent No. 7821631B1
U.S. Patent No. 8202059B1
U.S. Patent No. 8202733B1
U.S. Patent No. 8570500B2
U.S. Patent No. 9108196B1
U.S. Patent No. 9857284B1

Download Tech Specs

Colors/Filters

User Interchangeable Optical Filters:

Lasers# of ColorsColors/Filters
488 nm (Blue) Laser4FITC (530/30), PE (580/30), PerCP/PE-Cy5 (676/29), PE-Cy7 (740LP)
640 nm (Red) Laser2APC (676/29), APC-Cy7 (740LP)

Brochure