S1000EXi
Benchtop Flow Cytometer
_______________
The idea behind the S1000 platform has never wavered: to design the ultimate flow cytometer. The best fluidics, fused with patented optical technology and the most powerful lasers—all within a benchtop package. And that commitment continues with our all-new 4 laser, 18 color analyzer. Like the S1000 predecessors, the S1000EXi delivers an unrivaled flow cytometry experience.
Upgrade anytime. On the field. Add automation, lasers, colors, and more to always have the latest and cutting-edge technology. And with a standard two-year warranty, users know the best-in-class hardware is backed by the best-in-class service.
_______________
Features:
- Configurable and scalable up to 4 lasers and 18 colors
- Best in class two-year warranty
- Future-proof system with easy field upgrades
- Excellent resolution < 2.5% CV
- Industry-leading sensitivity < 100 MESF
- Extensive range of particle sizes from 0.2 µm to 40 µm
- Patent pending Laser-Trimming technology for detection of particles from 0.2 µm to 7 µm simultaneously
- Patented OptiSymmetric™ excitation architecture and Smart Detect™ technology
- Revolutionary Ghost Detect™ module for measurement of background fluorescence without a physical trigger
- Seamless integration with automation options
Literature
Technical Specifications
Laser:
- System is designed to support up to 4 lasers with spatial separation
- Laser options:
- Solid-state 405 nm – 100 mW
- Solid-state 488 nm – 150 mW
- Solid-state 532 nm – 100 mW
- Solid-state 640 nm – 100 mW
- Custom laser options:
- Solid-state 372 nm – 100 mW
- Solid-state 552 nm – 100 mW
- Solid-state 561 nm – 100 mW
- **Other lasers available upon request
Detector Parameters & Data Acquisition:
- Forward scatter (FSC) – enables separation of unfixed platelets from noise
- FSC resolution: < 500 nm polystyrene beads
- FSC scales: log & linear
- FSC: parameters: width, peak-height; area
- Optional FSC photomultiplier (PMT) detector
- Side scatter (SSC)- resolves lympho-, mono- , and granulocytes
- SSC resolution: < 200 nm polystyrene beads
- SSC scales: log & linear
- SCC parameters: width, peak-height, area
- Fluorescence channels:
- Standard number of colors: 18
- Sensitivity: < 100 MESF
- PMT scales: log & linear
- PMT parameters: width, peak-height, area
- Time: 13 μsec resolution
Analysis Rate & Carryover
- Analysis rate: 10,000 events/sec
- Carryover: <0.1% automatic backlash between samples
Sample Input:
- Dead volume: < 8 μL
- Minimum sample volume: < 20 μL
- Maximum particle size: 40 μm
- Patented low insertion force single tube loading
User Interchangeable Optical Filters:
- Blue laser dyes: FITC (530/30), PE (580/30), PE- Texas Red (615/30), PerCP/PE-Cy5 (676/29), PECy5.5 (690/40), PE-Cy7 (740LP)
- Red laser dyes: APC (676/29), APC-Cy5.5 (690/40), Alexa700 (710/40), APC-Cy7 (740LP)
- Green laser dyes: PE (580/30), PE- Texas Red (615/30), PerCP/PE-Cy5 (676/29), PECy5.5 (690/40), PE-Cy7 (740LP)
- Violet laser dyes: Pacific Blue/DAPI (445/60), AmCyan (530/30), Pacific Orange (580/30), QD605 (615/30), QD655 (676/29), QD655 (676/29), QD705 (690/40), QD800 (740LP)
- **Other dyes available upon request
Fluidics Tray:
- Integrated fluidics tray does not increase the footprint of the instrument
- Automated startup, shutdown, and cleaning cycles
- Automated decontamination procedure using onboard cleaning solution for all components in contact with sample
- Tank Capacity: 4 L sheath, 4 L waste, 4 L auxiliary solution
- Optional automated sheath tank fill and waste drainage
Operating Conditions:
- Operating Conditions: 60-86 °F (15-30 °C)
- Size (including fluidics tray): 21.5″ W x 21″ D x 24″ H (54.6 cm W x 53.3 cm D x 61 cm H)
- Weight (including fluidics tray): < 70 lbs (35 kg)
- Power: 110/115/230 VAC, 50-60 Hz
Brochure